EE SERIES ELECTROMECHANICAL LEVEL MEASURING SYSTEM

EE SERIES ELECTROMECHANICAL LEVEL MEASURING SYSTEM

Category: FINETEK

Specifications
Details

EE Series Electromechanical Level Measuring System

 

The EE300/EE400 Series is an electromechanical inventory level measuring system which uses state-of-the-art third generation weight & cable technology to periodically measure the level of liquid and bulk solid materials held in storage. The EE300/EE400 series level measuring system includes the EE300/EE400 sensor and available RCU remote control unit or MMS-TL PC-software.

The EE300/EE400 series electromechanical inventory level measuring system is a flexible inventory system that can consist of the EE300/EE400 sensor(s) only or can include the remote control unit (RCU) or MMS-TL materials management PC-software. The EE300 is a third generation weight & cable inventory level measuring sensor consisting of a sensing weight, heavy duty stainless steel cable, distance measuring component, position detection sensor and electronics (includes firmware). The EE300/EE400 electromechanical inventory level measuring system sensor detects the sensing weight status and measures the empty space distance within the vessel during a measuring cycle. Upon initiation of a measuring cycle the sensing weight and cable system is lowered into the vessel until the sensing weight contacts the material surface, which is detected by the position sensing system, then the sensing weight and cable system is raised and returned to the starting socketed position. When the measuring cycle is completed all EE300/EE400 electromechanical inventory level measuring system outputs and data are updated.
 

  • Microprocessor control of measuring cycle, diagnostics
  • Up to 98ft (30m) measuring range
  • Angle adjustment flange available, ≤45
  • Standard MODBUS serial link, 4-20mA and AC/DC pulse outputs
  • Three (3) relay outputs
  • Remote control unit (RCU) and PC-software available
  • Variety of sensing weights
  • No cable cutting required
  • Measure of empty space in silo for scheduling trucks
  • Inventory monitoring to ensure production schedules
  • Inventory alarm notifications

INDUSTRY

  • Plastic processing
  • Concrete production
  • Cement processing
  • Agriculture
  • Feed & grain processing
  • Food production
  • Chemical
  • Water/wastewater
No . Category EE300 EE400
1 Power supply 88~264Vac 50/60Hz 88~264Vac 50/60Hz
2 Auccuracy 1. Transistor output: NPN / PNP(10mm/pulse)
2. Relay output: 3A/250Vac
(100mm/pulse)
±3cm
3 Analog output 0/4-20mA ±1% 0/4-20mA ±1%
4 Ambient temperature ­35°C~60°C ­40°C 85°C(With Heater)
        ­30°C~85°C(Without Heater)
5 Operating temperature ­35°C~80°C ­40°C~105°C
6 Operating pressure ­­­­ max.+1.2bar
7 Measuring range max.30m(option:30~45m) max.30m
8 Measuring speed Avg. 0.23m/s Avg. 0.23m/s
9 Protection rating IP66 IP66
10 Body material Aluminum Aluminum
11 Display LCD (Dot matrix , 8 X 2) LCM (Graphic,128x64 Dots)
12 Status LED
LED Display:
1.Lock                 (Red) On
(Fill-Up Protection)
2.RUN             (Yellow) On
3.Buried            (Red) Blink for 1 second
4.Break              (Red) Blink for 2 seconds
5.Auto                (Blue) On
6.High Alarm   (Red) On
7.Low Alar        (Red) On
  LCM Display:      Lock
                                Buried
                                Break
Status Display       
13 Relay output SPDT 3A/250Vac X 3
1. HI Alarm
2. LO Alarm
3. Buried: Blink for 1 second when
alarm triggers
Break: Blink for 2 seconds when
alarm triggers
Lock: LED on when alarm triggers
SPDT 3A/250Vac X 3
(1. HI Alarm
2. LO Alarm or Buried,Break)
14 Operation instruction ­­­­ SPST 3A/250V X 1
15 Anti-Dew heater Start heating <16°C
( freeze prevention, prevent dew )
110/220Vac max. PF 96.8W
Start heating <16BC
( freeze prevention, prevent dew ) ,
110/220Vac max. PF 96.8W
16 Cable break detection Yes Yes
17 Plumb buried detection Yes Yes
18 Activating from outside Yes Yes
19 Motor limited current
protection
Yes Yes
20 Malfunction diagnosis
display
Yes Yes(alternatire of HI Alarm,Lo Alarm
or Buried alarm,Break alarm)
21 Material fill up
protection
Yes Yes
22 Material discharge
protection
No Yes
23 Intelligent start Yes (Measuring interval is inverse proportional to medium level)
24 Cable wire ø1.2mm/-- ø1.2mm/12mm*0.2mm
 

View more about EE SERIES ELECTROMECHANICAL LEVEL MEASURING SYSTEM on main site