Level and pressure measurement and point level detection in ointment production in batch mode
Category: Pharmaceutical
Specifications
Details
Batching tank for ointments
Level and pressure measurement and point level detection in ointment production in batch mode
Process data
Measuring task
Level and pressure measurement, point level detection
Measuring point
Reactor
Measuring range up to
10 m
Medium
Ointments and creams
Process temperature
+20 … +135 °C
Process pressure
-1 … +5 bar
Special challenges
Frequent, extreme temperature changes in batch mode (cleaning), tank internal structures and mixers
Application
Many different ointments and creams are produced in batching tanks. The process conditions in batch production are typically characterized by high temperatures and vacuum. After each batch run, the tank needs to be cleaned quickly and effectively with chemically aggressive cleaning agents ready for the next batch. Contamination of the products during the mixing or reaction process is prevented by the use of a protective gas atmosphere. To ensure a safe, reliable process, both the level and the gas head pressure must be continuously monitored.
Your benefit
Reliable
Certified materials in compliance with FDA and EC 1935/2004
Cost effective
Maintenance-free operation
User friendly
Easy installation
Recommended products
VEGABAR 83
Level, pressure and electronic differential pressure measurement with two pressure transmitters in the batching tank
- By measuring the pressure in the upper and lower region of the tank, both the gas head pressure and the level can be reliably monitored
- The thermally self-compensating METEC® measuring cell measures accurately and reliably – despite cleaning-related thermal shock
- Hygienic process fittings are ideal for use in sterile production processes
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 1000 bar
Process temperature
-40 ... 200 °C
VEGASWING 61
Point level detection with vibrating level switches in batch operation
- Reliable detection of the limit level, regardless of the product or process properties
- Hygienically optimised process fittings ensure easy cleaning and maximum process safety
- Easy to install, even the very smallest process fittings are possible
Measuring range - Distance
-
Process temperature
-50 ... 250 °C
Process pressure
-1 ... 64 bar
View more about Level and pressure measurement and point level detection in ointment production in batch mode on main site