Differential Pressure Transmitters (ALDPT with ACONE)
Category: Differential Pressure Flowmeter
Specifications
Styles
Differential Pressure
Sizes
Any
Measuring range
Available for DP of up to 0 -2Mpa (290 PSI)
Process Temperature
4-752°F(-20- 400)°C
Accuracy
±0.5%, ±0.2%, ±0.075% of reading
Metering tube
SS #316L, Hastelloy C, Tantalum, Gold Plated
Outputs & Electronics
4~20 mA square root output, HART, MODBUS
Connection
“-18 NPTF & "-20 UNF, no drain or with drain top, side or bottom of flange
Process Medium
3 or 5-way valve manifold for primary DP flow element (ACONE), 2" pipe mounting brackets, O2 cleaning, capillaries (many fill fluids)
Application
Stand alone DP measurement or with primary flow elements: Orifice, Venturi, ACONE, Pitot Tube, Wedge, Elbow
Details
The ALDPT-3051 is an intelligent differential pressure transmitter making use of advanced microprocessor technology with digital communication. This instrument makes use of advanced capacitive sensor technology and is capable of measuring all three media phases – liquids, gasses, and steam. The ALDPT-3051 includes an array of features including self-diagnostic capability, field-adjustable parameter settings, and auto-zeroing at a much lower price versus competitive offerings. Available outputs include 4-20 mA, 1-5 VDC, HART, and Foundation Fieldbus. The wide selection of materials of construction, optional accessories, and communication outputs available for the ALDPT-3051 make it suitable for nearly any differential pressure measurement application.
Measuring range: | 0~1kPa~2MPa |
Fluid: | liquid, gas and steam |
Ambient temperature: | -22~185°F (–30°~85°C); -4~149°F (20°~65°C) Fluorine Line |
Fluid media: | liquid, gas and steam |
Accuracy grades: | 0.075%, 0.2%. 0.5% |
Process flange: | SS# 304, SS# 316-optional |
Turn-down: | 100:1 |
Drift (Micro): | 0.02% FS/year; Standard: 0.025% FS/year |
Relative humidity: | 0 ~ 100% RH |
Damping time: | 2 sec |
Protection: | IP67/NEMA 6 |
Start time: | 2 seconds after power up |
Field indication: | LCD |
Storage temperature: | -58~185°F (50~85°C) No display; -40~185°F (-40~85°C) LCD display |
Weight: | 7.25 ~11lbs (3.3 ~ 5kg) |
Working voltage: |
(12~36 ) VDC —Blind type; (15~30 ) VDC; LCD type |
Isolation diaphragm: | SS# 316 or Hastelloy C |
Nuts & bolts materials: | Stainless steel |
Communications distance: | 2 km when using CEV cable; Load capacity: below 0.22μF; Load inductance: below 3.3 mH |
Approvals: | ExdIICT6 -ATEX, ExiaIICT4 -ATEX |
Transmitter housing: | Aluminum with epoxy coating; Spacing with power line: 15 cm; Resolution: 0.05% of range |
Fill Fluid: | Silicon oil, fluorocarbon oil |
O-ring materials: | Nitrile, Viton, PTFE |
Effects: | Effect of environmental temperature: Zero drift: 0.5% FS/50°C; Range drift: 0.7% FS/50°C; Effect of power voltage variation: ±0.005% FS/V |
Output signals: | 4~20 mA DC two wire |
Refer to the link for more details: https://www.smartmeasurement.com/differential-pressure-transmitters/
View more about Differential Pressure Transmitters (ALDPT with ACONE) on main site