VEGABAR 83 - Metallic Pressure Transmitter

VEGABAR 83 - Metallic Pressure Transmitter


Specifications
Measuring range - Pressure
-1 ... 1000 bar
Process Temperature
-40 ... 200 °C
Process Pressure
-1 ... 1000 bar
Accuracy
0.075 %
Materials, wetted parts
- 316L - Alloy C22 (2.4602) - 316Ti (1.4571) - Alloy C4 (2.4610)
Threaded connection
≥ G, ≥ NPT
Flange connection
≥ DN25, ≥ 1"
Hygenic fittings
- Slotted nut ≥ DN25 - DIN 11851 - Varivent ≥ DN25 - hygienic fitting with tension flange DN32 - Hygienice flange connection ≥ DN50 DIN11864-2 - SMS 1145 DN51 - SMS DN38 - Hygienic fittings ≥ DN33 - DIN11864-1-A - Hyg. collar clamp adapter DN40PN40 DIN11864-3-A - Hyg. clamp connection DIN11864-3-A; DN50 Rohr 53 - Swagelok VCR screwing - Varivent G125
Seal Material
no media contact
Housing Material
- Plastic - Aluminium - Stainless steel (precision casting) - Stainless steel (electropolished)
Protection rating
- IP66/IP67 - IP66/IP68 (1 bar) - IP68 (0,2 bar) - IP66/IP68 (25 bar) - IP69K
Output
- Profibus PA - Foundation Fieldbus - 4 … 20 mA - 4 … 20 mA/HART - two-wire - Modbus - Secondary electronics for electronic differential pressure
Ambient temperature
-40 ... 80 °C
Approvals
- ATEX / Europe - CSA / Canada - FM / USA - EAC (GOST) / Belarus - EAC (GOST) / Russia - IEC / worldwide - INMETRO / Brazil - CCOE / India - CSA / USA and Canada
Explosion Protection
- Intrinsic safety "i" - Flameproof enclosure "d" - Dust explosion protection through housing "t"
Foodstuffs/Pharma
- 3A - EHEDG - FDA - EG1935/2004
Ship Approval
- ABS - BV - CCS - DNV - GL - LR - RINA
Overfill protection
- WHG - VLAREM II
SIL qualification
SIL2
Display & adjustment
- PLICSCOM - PC, PACTware and DTM - HART-Communicator - Software (e. g. AMS, PDM)
Indication
- Display/adjustment module PLICSCOM - VEGADIS 81 - VEGADIS 82
Details

 

Pressure transmitter with metallic measuring cell

With metallic measuring cell, for high pressures

Application area

For measurement of liquids and viscous products with high process pressure.

The VEGABAR 83 is a pressure transmitter for pressure measurement of gases, vapours and liquids in all industries. The VEGABAR 83 offers special advantages in applications with high pressures. The simple connection of VEGABAR series 80 sensors as electronic differential pressure opens new possibilities for the measurement of differential pressures.

 

Your benefit

  • Maximum dependability and safety through proven technology
  • High reliability through vacuum resistant version
  • Universal use due to welded measuring cell
 
Technical Specifications
Measuring range - Pressure  -1 ... 1000 bar
Process temperature  -40 ... 200°C
Accuracy  0.075%
Materials, wetted parts
  •  316L
  • Alloy C22 (2.4602)
  • 316Ti (1.4571)
  • Alloy C4 (2.4610) 
Process connection
  • Thread from ≥ G½, ≥ ½ NPT
  • Flange from ≥ DN25, ≥ 1''
  • Hygenic fittings of 316L
  • Alloy
Housing Material
  • Plastic 
  • Aluminium 
  • Stainless Steel (precision casting)
  • Stainless Steel (electropolished)
Output
  • Profibus PA
  • Foundation Fieldbus
  • 4 ... 20 mA
  • 4 ... 20 mA/HART - two-wire
  • Modbus
  • Slave electronics for electronic differential pressure
Approvals  ATEX, CSA, FM, EAC (GOST), IEC, INMETRO, CCOE, CSA, Foodstuffs/Pharma, Ship, Overfill protection, SIL2

Refer to the link for more details: https://www.vega.com/en/home_de/products/product-catalog/pressure/process-pressure/vegabar-83

View more about VEGABAR 83 - Metallic Pressure Transmitter on main site