VORTEX MASS VORTEX FLOW METER (ALVT-MASS)

VORTEX MASS VORTEX FLOW METER (ALVT-MASS)

Category: Vortex Flowmeter

Specifications
Sizes
-12" (15-300 mm)
Temperature
-23~482 °F ( -5 ~ +250 °C)
Accuracy
1.5% gas/steam, 1% liquids
Viscosity
1 to 10 cSt
Operating Pressure
Up to 920 psi (6.4MPa)
Material
SS #304 (standard) SS #316 (optional)
Signal Output
4-20mA, pulse, Modbus, HART
Process Connection
Flanges (ANSI, DIN & JIS), Wafer
Process Medium
Steam, liquid, gas
Application
Best solution for steam, limited liquid and gas applications
Details

Vortex flow sensing technology relies on measuring the number of vortex pulses generated by a bluff body immersed in the flow stream. The SMC Vortex meter uses dual sensor technology, producing two independent vortex signals which allows for signal amplification and common mode noise reduction. The ALVT-mass is our multivariable vortex meter with a high-accuracy velocity sensor, a precision platinum RTD temperature sensor, and a pressure transducer with flow outputs for both volumetric and mass flow rates. 

Our sensors never touch the process fluid; the piezo electric crystal flow sensors are bonded behind a stainless steel wall. The electronics pick up the slightest pressure pulsations generated by the vortices through the stainless steel wall. This design allows meters to have an extremely wide turndown while maintaining an almost unlimited upper end and a high-pressure rating. 

  • Mass Flow Vortex
  • ½-12" (15-300 mm)
  • -23~482 °F ( -5 ~ +250 °C)
  • 1.5% gas/steam, 1% liquids
  • 1 to 10 cSt
  • Up to 920 psi (6.4MPa)
  • SS #304 (standard) SS #316 (optional)
  • 4-20mA, pulse, Modbus, HART
  • Flanges (ANSI, DIN & JIS), Wafer
  • Steam, liquid, gas
  • Best solution for steam, limited liquid and gas applications
Features
  • Includes velocity, temperature and pressure transducers to calculate mass flow rates
  • Suitable for a wide variety of applications with steam, gas, and liquid medias
  • No moving parts and no leak paths; no O-ring or graph oil seals to wear, fail or leak
  • Two independent piezo-electric sensors, allowing for better signal amplication and noise reduction
  • Error messages displayed for erratic flows and flows outside of calibrated ranges
  • Field calibration possible with integral or remote electronics and keypad
  • True 2-wire 4-20 mA interface
  • Wide measuring range, turn-down ratio of 30:1
  • Can measure at Reynolds Numbers ranging from 10,000 to 7,000,000
  • Weather proof multi-pole connector for power, signal and serial interface
  • Available in both integral or remote mass flow versions
Specifications
 
Process Connections: Threaded, Flanged, Ball Valve, Weldolet
Process temperature: 32 to 590 °F (0 to +310 °C)
Operating pressure: up to 985 psi (68 bar)
Velocity Range: Depends on fluid, pressure and temperature:Liquids: ≤ 1.5~30 feet/sec (0.4~9 m/s)Gas & Steam: 5-300 fps (1.5-90)
Accuracy (and linearity): ± 1% of Reading
Repeatability: ± 0.25% of Reading
Turn down ratio: > 30:1
Material : 316SS or Carbon Steel
Signal output: 2-wire 4-20ma, Pulse
Display: 2 Lines, 16 Alphanumeric Characters Each
Keypad: 4-button membrane type
RAM Back-up: Lithium Battery
Data logger: 16K, sampling times from 1 to 256 minutes
Electronics: NEMA 4X/IP 66, CE
Ex-protection: UL, CSA, FM, Class I Group B, C, D, Class II Groups E, F, G
Cable (remote version): 300′ (90 meters) max
Weight (approximate): ALVTN-S :13 to 17 lbs (6 to 8 kg)ALVTN-H :17-26 lbs (8-12 Kg)ALVTN-W 20-200 : 4-26 lbs (2-12 Kg)ALVTN-F 20-300 : 2-110 lms (4-50 Kg)
Communication: RS232
Power requirements : 110/220 VAC, Isolated 14 – 36 VDC
NIST traceable: Liquids and gasses only
Data storage: EPROM storage up to 10 years

Refer to the link for more details: https://www.smartmeasurement.com/alvt-mass-flowmeter/

View more about VORTEX MASS VORTEX FLOW METER (ALVT-MASS) on main site