DELTA-TUBED CORIOLIS MASS FLOW METER (ALCM-DT)
Category: Coriolis Mass Flowmeter
Specifications
Type
Delta Tube Coriolis
Process Medium
Liquids
Sizes
"-1" (3-25mm)
Process Temperature
-58-356°F (-50-180°C)
Accuracy
± 0.1, 0.15, 0.2 and 0.5% of reading
Process Connection
Flanged (ANSI, DIN, JIS, Sanitary)
Liquid requirement
Low flows, small pipe sizes
Application
Chemical, Pharmaceutical, Automotive, Food & Beverage
Details
SmartMeasurement’s ALCM-DT delta-tubed Coriolis mass flow meters use two tubes formed into a triangle shape, or delta, in a parallel arrangement. These delta tubes are vibrated at their resonant frequency by coils. Any mass flow passing through the tubes will generate Coriolis forces, which are created whenever a mass moves radially in a rotating system. These forces have opposite effects on the inlet and outlet sides, deforming each tube by a minor amount.
SmartMeasurement’s Delta-Tubed Coriolis Mass Flow Meters
The delta tube geometry of these liquid flow meters provides outstanding low-flow performance versus other Coriolis tube geometries, making this instrument an ideal choice for applications with smaller line sizes and lower flow rates.How Do Delta-Tubed Coriolis Mass Flow Meters Work?
The ALCM-DT delta-tubed Coriolis mass flow meter’s circuitry also makes it possible to determine conversions such as volumetric flow, percent concentration, and percent water-cut.
- Delta Tube Coriolis
- Liquids
- Sizes "-1" (3-25mm)
- -58-356°F (-50-180°C)
- ± 0.1, 0.15, 0.2 and 0.5% of reading
- Flanged (ANSI, DIN, JIS, Sanitary)
- Low flows, small pipe sizes
- Chemical, Pharmaceutical, Automotive, Food & Beverage
- Measurement of mass flow, density, temperature & volume flow
- Suitable for aggressive & contaminated media
- Measurement & display of percent water-cut for oil/water mixtures
- Excellent purging & sterilization capabilities thanks to dead spot-free construction
- High rotation frequency & well-balanced measuring tubes
- Operates at temperatures up to 575°F (300°C)
- Individual 8-point calibration including NIST-traceable report
- Optional EX protection
Flow Range: | 150~900,000 kg/hr |
Process Connections: | Flanged (ANSI, DIN, Tri-Clamp®) |
Line Sizes: | ½”~8”(15-200 mm) |
Process temperature: | -76~662 °F (-60~350 °C) – Remote; -76~257 °F (-60~125 °C) – Integral |
Tube geometry: | Delta-Tube |
Accuracy: | ±0.5% of reading(std), 0.2% or 0.15% (opt) |
Repeatability: | ±0.05% of reading |
Engineering Units (Mass): | kg, lb, ton |
Display: | Dot-Matrix LCD |
Engineering Units (Temp.): | °C, °F |
Engineering Units: (Volume): | m³, Liter, US Gallon, Imperial Gallon |
Zero Stability: | 0.1% full-scale |
Zero Drift (%FS / °C): | 0.005 |
Max Working Pressure: | 580 psig (4.0 MPa) |
Measuring Tube Mat’l: | SS #316L |
Power Supply: | 12~28 VDC, 86~260VAC,50~60Hz |
Housing Material: | SS #304 |
Outputs: | 4-20 mA, frequency, pulse, RS485 |
Power Consumption: | Less than 12W |
Density Measuring Range: | 43.7-81.2lb/ft³ (0.7~1.3 g/cc) |
Temperature Measuring Range: | -76~662 °F (-60~350 °C) – Remote; -76~257 °F (-60~125 °C) – Integral |
Density Accuracy: | ±0.06 b/ft³ (0.001 g/cc) |
Temperature Accuracy: | ±0.5 °C |
Refer to the link for more details: https://www.smartmeasurement.com/delta-tubed-coriolis-mass-flow-meter/
View more about DELTA-TUBED CORIOLIS MASS FLOW METER (ALCM-DT) on main site