GEAR POSITIVE DISPLACEMENT METER (ALGPD)

GEAR POSITIVE DISPLACEMENT METER (ALGPD)


Specifications
Styles
Standard Gear PD for low flows
Sizes
”~1" (8-40mm)
Measuring range
0.01~110 GPM (0.04~416 LPM)
Process Temperature
up to 400°F (200°C)
Accuracy
±0.5% RD
Viscosity
5 to 25,000 cSt
Process Pressure
6000 psig (410 barg)
Metering tube
SS #304 & SS #316
Outputs & Electronics
TTL/CMOS PNP or NPN Open Collector, 0-5VDC pulse
Connection
0-5 VDC
Process Medium
Hydraulics, lube oil, batch control
Application
Automotive, Fluid Power, Aerospace
Details

The SMC series ALGPD Gear flow meter is suitable for the precise flow measurement of various fluids of viscosities from 5 up to 25k mm²/s. Providing sufficient lubricity of the fluid, the small gear flow meters type ALGPD 01/1 and 02 as well as ball bearing versions may also be used for fluids below 5 mm²/s. Gear flow meters are positive displacement meters, similar in design to a gear pump. The measuring medium rotates two gears, which are engaged with minimum play. The medium is forced along through closed measuring chambers between gears and housing. The gears, which run idle, lose no power. The RPM of the gears is in proportion with the instantaneous flow rate and precisely detected by integral pickups through the body of the meter without contacting the fluid. The flow signal can be displayed our various other electronics. We calibrate our flow meters to match the customer’s operating viscosities to determine their K factors.

Features
  • High output frequencies resulting in good resolution and suitable for pulsating flows.
  • Reverse-flow detection and pulse multiplication functions
  • Ex-protection EExiaIICT6/T4
  • Resistance to high voltage from 50 kV up to 120 kV
  • Special meters with high-pressure connectors for service up to 690 barg (10,000 PSIG).
  • Heated versions are available on request
  • The K-factor (no. of pulses per liter) is nearly constant over a wide range.
Specifications
Flow Range: 0.005 to1000 LPM (.001 to 264 USGPM)
Process temperature: up to 356 °F (180 °C)
Line size: ¼” 1½” (8-40mm)
Operating pressure: up to 10,000PSIG (690 barg)
Accuracy: ±0.25% of value for viscosities 50 to 25,000 centistokes
Body Material: SS as per DIN 1.4122/AISI 303 or 1.4460/AISI 329
Repeatability: ±0.10%
Enclosure Rating: NEMA 4X (IP 65)
Viscosity: 5 up to 25,000 centistokes
Display: rate, total, low flow cut-off, battery consumption
Housing Protection: IP65; IP67; IP68
Frequency Range: 2 up to 4,000 Hz
Ambient temperature: -22 to 158°F (-30 to +70°C)
Working Humidity: < 90% @ 75°F
Supply Voltage UB: 14-30VDC controlled, UB=(Rload x 20 mA)+ 14V
Ex-protection: II 2 G Eex ia IIC T4, BVS 03 ATEX E 205
User Parameters: K-factors, linear correction coefficeint, flowrate input signal section points, temperature
Housing: IP 68, aluminum AlMgSiPb, blue anodized
Output: pulse, 4-20 mA or RS485

Refer to the link for more details: https://www.smartmeasurement.com/gear-positive-displacement-meter/

View more about GEAR POSITIVE DISPLACEMENT METER (ALGPD) on main site